Add to Cart
Hydraulic Sequence Valve High Operation Pressure Simple Installation Carbon Steel Body
SPECIFICATION
Model No. | CLG-3A | CLG-6A |
Adjustable pressure range MPa | 1.0~6.0 | 5.0~18.0 |
Operating pressure range MPa | 2.0~35.0 | 6.0~35.0 |
Adjustable screw pressure change value MPa/Rev | 1.0 | 2.8 |
Starting pressure MPa | 0.01 | |
Operating temperature °C | 0~70°C | |
Useable fluid | hydraulic oil equivalent to ISO-VG-32 |
Note:
Excessive side oil supply can sometimes result in inaccurate sequential actions.
Install a flow control valve with a built-in check valve in front of the oil hole or
execute flow control on the oil pressure source.
Ordering Code:
CLG - 3 A(5.0MPa)
1 2 3 4
1 | Series | CLG |
2 | adjustable pressure range | 3: 1.0~6.0 MPa 6: 5.0~18.0MPa |
3 | A | Manifold type |
4 | Pre-set pressure (Set pressure value for sequence operation) | Provide a difference of more than 1MPa between operating and setting pressure. |